nif:isString
|
-
To verify ON-induced axonal disintegration, visual evoked potentials (VEP) were recorded before GC-treatment in at least two trials for each eye, averaging >150 responses, with electrodes positioned at Oz (active) and Fz, in accordance with the International Society for Clinical Electrophysiology of Vision (ISCEV) standards [28].
|